technical details TOPLINE
|
|
|
|
|
|
|
|
structural lighting elements
|
|
|
|
|
|
|
|
Circular shaped polycarbonate multiple boards. Thickness: 16 mm. The exterior side is coextruded to optimise weathering resistance and additionally coloured opal to absorb thermal energy irradiation or coated with a heat protection agent.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
16mm / 3 boards
|
|
16mm / 5 or 6 boards
|
|
|
|
|
|
|
|
|
|
|
|
K-value:
|
2,4 W/m²K
|
|
1,8 W/m²K
|
|
|
|
|
|
|
|
|
|
|
|
Transparency (colourless):
|
ca. 72 %
|
|
ca. 63 % / ca. 59 %
|
|
|
|
|
|
|
|
|
|
|
|
Transparency (opal coloured):
|
ca. 52 %
|
|
ca. 47 % / ca. 47 %
|
|
|
|
|
|
|
|
|
|
|
|
max.temperature of use:
|
115 °C
|
|
115 °C
|
|
|
|
|
|
|
|
|
|
|
|
fire behaviour to DIN 4102:
|
B2
|
|
B2
|
|
|
|
|
|
|
|
|
|
|
|
ball resistance to DIN 18032:
|
unbreakable, also to hockey balls
|
|
|
|
|
|
|
|
|
|
|
|
resistance to hail:
|
according to manufacturer specification
|
|
|
|
|
|
|
|
|
|
|
|
snow load:
|
according to type statics, higher load on request
|
|
|
|
|
|
|
|
|
|
|
|
wind suction stability:
|
up to 0,80 kN / m²
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Integrated smoke extraction systems
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Conforming to DIN EN 12101-2 and VdS regulations (Insurance Firms Union).
|
|
|
|
|
|
|
|
|
|
|
|
For clear openings widths of 1,50 m
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Ventilation damper:
|
|
1,50 x 1,10 m and 1,50 x 2,30 m. Opens electrically or pneumatically.
|
|
|
|
|
|
|
|
|
|
|
|
Smoke and heat venting flap:
|
|
1,50 x 1,10 m and 1,50 x 2,30 m. Fitted with opening mountings, pneumatic cylinder, thermal release. The flap opens automatically if the temperature to 68°C.Opening angle: 150° Manual opening is possible by means of an alarm box and CU pipework.
|
|
|
|
|
|
|
|
|
|
|
|
For clear opening widths of 1,98 m and more
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Ventilation flap:
|
|
1,98 * 1,10 m und 1,98 * 2,30 m.
|
|
|
|
|
|
|
|
|
|
|
|
Smoke and heat venting flap:
|
|
1,98 * 1,10 m und 1,98 * 2,30 m.
|
|
|
|
|
|
|
|
|
|
|
|
Certified by Institut für Bautechnik Berlin Z-10.1-343 (Soft roofing) and Z-10.1-344 (Hard roofing)
|
|