lt. 1: Indu-Light-Topline
Skylight made using polycarbonate multiple web panels, building-regulations approved under No Z-10.1-343, manufactured using circularly bent multiple web panels. The exterior face is co-extruded (longlife) for optimized weather resistance. The polycarbonate panels drip off in a non- inflamed state, and they are ready-to-melt-out acc. to DIN 18230. All components of the continuous rooflight are 100 % recyclable. For a reduced heat transmittance, the elements are opalescent. Extruded profiles are used to joint the panels both inside and outside. The system is mounted in such a way that the PC elements are free to extend in all directions. So they do not need to be through-bolted. The head sections are also made using PC multiple web panels. The continuous rooflight is designed for a snowload of 0.75 KN/m² and a wind load of 0.90 KN/m², and it is ready for assembly onto a steel crown.
Clear opening: Length m, Width m
Pcs.
16mm PC-S3P, Kg= 2,40 W/m²K, opal / transparent 16mm PC-S5P, Kg= 1,80 W/m²K, opal / transparent 16mm PC-S5P, Heatstop 20mm PC-S6P, Kg= 1,67 W/m²K, opal / transparent 20mm PC-S6P, Heatstop
It. 1.1: Extra offer Topline Plus For use in conjunction with Indu-Light Topline for a system thermal insulation continuous rooflight with a total K value of K = 1.8 W/m²K for continuous rooflight and frame. Test certificate No 1001930-03-04-05.
20/31/05.05 TOPLINE – Skylight SystemTOPLINE
It. 2: Hard roof cladding
for use in conjunction with the continuous rooflight (DIN 4102 Part 7), comprising a glass-fiber reinforced polyester resin panel made from textile-glass reinforced unsaturated polyester resin, resistant against flying sparks and radiant heat.
Clear opening: Length m, Width m
Pcs.
It. 3: Heatstop glazing
for use in conjunction with the continuous rooflight comprising a highly reflecting surface providing an additional reduction of the heat transmittance.
Pcs.
It. 4: Full-perimeter crown (supported)
Steel sheet thickness acc. to static requirements, 450 mm height, galvanized, arranged vertically, ready for assembly of a 80 mm thermal exterior insulation provided by customer, supported, including the required diagonal ties and struts.
Pcs. each running meter.
It. 5: Full-perimeter crown (unsupported)
Steel sheet thickness acc. to static requirements, 450 mm height, galvanized, arranged vertically, ready for assembly of a 80 mm thermal exterior insulation provided by customer, unsupported for a support-to-support distance up to 7.50 m, including the required diagonal ties and struts.
Pcs. each running meter.
20/32/05.05 TOPLINE – Skylight SystemTOPLINE
It. 6: Crown adapter profiles
Material thickness acc. to static requirements, blank ca. 250 mm, galvanized, adapted to existing frame head for accommodation of the Proline continuous rooflight.
Pcs. each running meter.
It. 7: Crown coating
to be used in conjunction with the steel crown, installed by customer, similar to RAL 9002, coil-coated.
Pcs. each running meter.
It. 8: Crown insulation
to be used in conjunction with the steel crown, comprising an 80 mm thick mineral-fibre insulation – thermal conductivity group 040, (for trapezoidal sheet or ISO roofs).
Pcs. each running meter.
It. 9: Crown insulation – PU insulation
to be used in conjunction with the steel crown, comprising 80 mm thick PU rigid foam panels laminated on one side – thermal conductivity group 030, (for foil or bitumen roofs).
Pcs. each running meter.
20/33/05.05 TOPLINE – Skylight SystemTOPLINE
It. 10: Crown film
Assembly of a roof foil strip provided by customer for installation between the crown and the continuous rooflight. This item includes the laying and workmanlike welding of the corner section. Complete sealing to the roof covering is conducted by customer.
Pcs. each running meter.
It. 11: Crown cover plate
to be used in conjunction with the steel crown, comprising an edged 1.0 mm thick aluminium plate, as-rolled finishing, mounted as top flashing, ready for accommodation of the existing roof connection plate.
Pcs. each running meter.
It. 12: Crown connection plate
to be used in conjunction with the steel crown, two-piece plate, comprising a sheet-aluminium top flashing, as-rolled finishing, and a bottom sheet-steel flashing, coated using a RAL colour at customer’s choice, ready for connection to an existing roof, including profile filler.
Pcs. each running meter.
20/34/05.05 TOPLINE – Skylight SystemTOPLINE
It. 13: Ventilation damper EL 1.10 m x 1.98 m
for use in conjunction with the continuous rooflight incl. the electrical ventilation system comprising an electric motor 230 V/50 Hz, 300 mm Hub, continuously variable, with automatic shut-off. Wiring and cabling is performed by customer.
Pcs.
It. 14: Ventilation damper PN 1.10 m x 1.98 m
for use in conjunction with the continuous rooflight incl. the pneumatical ventilation system comprising an pneumatical cylinder 300 mm Hub, operating pressure 5 – 8 bar, diameter 32 mm, secured in both extreme positions.
Pcs.
It. 15: SHE damper 1.10 m x 1.98 m
for use in conjunction with the continuous rooflight as smoke and heat exhausting (SHE) device according to DIN EN 12101-2, Aw = 1,634 m², incl. the automatic pneumatical natural smoke exhausting system comprising a crossbeam, a pneumatic cylinder, a thermal trigger incl. CO2 cartridge (opening at 68 °C).
Pcs.
It. 16: SHE damper 2.30 m x 1.98 m
for use in conjunction with the continuous rooflight as smoke and heat exhausting (SHE) device according to DIN EN 12101-2, Aw = 3,188 m², incl. the automatic pneumatical natural smoke exhausting system comprising a crossbeam, a pneumatic cylinder, a thermal trigger incl. CO2 cartridge (opening at 68 °C).
Pcs.
20/35/05.05 TOPLINE – Skylight SystemTOPLINE
lt. 17: Single-casement domelight SHE – double wing
Nominal dimension: m / crown: cm
for use in conjunction with the continuous rooflight as smoke and heat exhausting (SHE) device according to DIN EN 12101-2 incl. the natural smoke exhausting system. Automatic opening at 68 °C or manually triggering with an alarm unit connected by pipes. The mounting is possible at the crown or the mounting bars.
Pcs.
mounting between head ends
mounting at the mounting bars
mounting at the start or the end of the roof light
lt. 18: emergency finned ventilator
Nominal dimension: m / crown: cm
for use in conjunction with the continuous rooflight as smoke and heat exhausting (SHE) device according to DIN EN 12101-2 incl. the natural smoke exhausting system. Automatic opening at 68 °C or manually triggering with an alarm unit connected by pipes. The mounting is possible at the crown or the mounting bars.
Pcs.
mounting between head ends
mounting at the mounting bars
mounting at the start or the end of the roof light
20/36/05.05 TOPLINE – Skylight SystemTOPLINE
It. 19: Ventilation system EL 300 mm Hub
for use in conjunction with the damper of the natural smoke exhaust system, comprising an electric motor 230 V/50 Hz, 300 mm Hub, continuously variable, with automatic shut-off. Wiring and cabling is performed by customer.
Pcs.
It. 20: Ventilation system PN 300 mm Hub
for use in conjunction with the damper of the natural smoke exhaust system, comprising a pneumatic cylinder, 300 mm Hub, operating pressure 5 – 8 bar, diameter 32 mm, secured in both extreme positions.
Pcs.
It. 21: Surface type push button
for operating the electrical ventilation system (“OPEN” - “SHUT”). Wiring and cabling is performed by customer.
Pcs.
It. 22: Automatic wind and rain shutter
for safely closing the ventilation damper in case of precipitations, snowfall, heavy fog or high wind speed, comprising a surface-mount switch and control box and a heated rain sensor plate and an electronic anemometer. The dampers can be opened manually after the rain sensor plates are dry again. Wiring and cabling is performed by customer.
Pcs.
20/37/05.05 TOPLINE – Skylight SystemTOPLINE
It. 23: Alarm box (“OPEN”)
surface type, for manual activation of the natural smoke exhaust system, red painting, including one CO2 cartridge, lock, break glass and a striker valve.
Pcs.
It. 24: Alarm box (“OPEN” with electric supply)
surface type, red painting, including one CO2 cartridge, lock, break glass and a striker valve, plus electromagnet (12V, 24V or 230V) for tripping of the natural smoke exhaust system through the control unit of the fire-alarm or natural smoke exhaust system provided by customer.
Pcs.
It. 25: Alarm box (“OPEN” / “SHUT”)
surface type, for manual activation of the natural smoke and heat exhaust system. Comprising a lockable steel sheet enclosure, red painting, including two CO2 cartridges, reverse valve, lock, break glass and a striker valve.
Pcs.
20/38/05.05 TOPLINE – Skylight SystemTOPLINE
It. 26: Single-line compressed-air pipe
Cu pipe, 6mm * 1mm, c / w threaded assembly and fixing work. Charges will be based on installed dimensions. Installation visible “Surface-Mount”.
Pcs. each running meter.
It. 27: Twin-line compressed-air pipe
Cu pipe, 6mm * 1mm, c / w threaded assembly and fixing work. Charges will be based on installed dimensions. Installation visible “Surface-Mount”.
Pcs. each running meter.
It. 28: Pneumatic valve compatible
(“OPEN-SHUT”“), for controlling the pneumatic ventilation facility, comprising an air control block including threaded assembly, steel sheet enclosure, surface type, light blue painting, compatible with CO2 alarm box as priority control.
Pcs.
20/39/05.05 TOPLINE – Skylight SystemTOPLINE
It. 29: Maintenance unit
comprising a moisture separator with manometer and pressure reducer (compressed-air supply is provided by customer).
Pcs.
It. 30: VdS acceptance
Charges for an individual acceptance of the natural smoke exhaust system acc. to DIN EN 12101 or VdS 2159 to be conducted by the Verband der Schadensversicherer e.V. Köln as requested by the builder-owner.
Pcs.
It. 31: Expert acceptance
Acceptance of the natural smoke exhaust system acc. to DIN 18232 conducted by smoke and heat exhaust experts.
Pcs.
20/40/05.05 TOPLINE – Skylight SystemTOPLINE
It. 32: Random method
Charges for participation in the random testing of the natural smoke exhaust system conducted by VdS, issue of a certificate on the compliance of the natural smoke exhaust system acc. to DIN EN 12101 and / or VdS 2098/ 2159.
Pcs.
It. 33: Assembly flatrate
for carriage, travel to the site, construction site equipment, offloading and transportation onto the roof.
Pcs.
It. 34: Flat-rate freight charge
for delivery free on site, w/o offloading, w/o assembly
Pcs.
|
|