headline3

flag_germany 

 

 

 

 

 

 

bill of quantity TOPLINE

 

 

 

 

 

Download PDF

 

 

Download GAEB

 

 

LV Generator

 

 

 

 lt.   1:  Indu-Light-Topline 

Skylight made using polycarbonate multiple web panels, building-regulations approved under No Z-10.1-343, manufactured using circularly bent multiple web panels. The exterior face is co-extruded (longlife) for optimized weather resistance. The polycarbonate panels drip off in a non- inflamed state, and they are ready-to-melt-out acc. to DIN 18230.  All components of the continuous rooflight are 100 % recyclable. For a reduced heat transmittance, the elements are opalescent. Extruded profiles are used to joint the panels both inside and outside. The system is mounted in such a way that the PC elements are free to extend in all directions.  So they do not need to be through-bolted. The head sections are also made using PC multiple web panels. The continuous rooflight is designed for a snowload of 0.75 KN/m² and a wind load of 0.90 KN/m², and it is ready for assembly onto a steel crown.

Clear opening: Length           m, Width            m

         Pcs.


16mm PC-S3P, Kg= 2,40 W/m²K, opal / transparent
16mm PC-S5P, Kg= 1,80 W/m²K, opal / transparent
16mm PC-S5P, Heatstop
    20mm PC-S6P, Kg= 1,67 W/m²K, opal / transparent
    20mm PC-S6P, Heatstop


It.  1.1:  Extra offer Topline Plus
For use in conjunction with Indu-Light Topline for a system thermal insulation
continuous rooflight with a total K value of K = 1.8 W/m²K for
continuous rooflight and frame.
Test certificate No 1001930-03-04-05.




 


20/31/05.05
TOPLINE – Skylight SystemTOPLINE
 

 It.   2:  Hard roof cladding

for use in conjunction with the continuous rooflight (DIN 4102 Part 7),
comprising a glass-fiber reinforced polyester resin panel made from textile-glass reinforced
unsaturated polyester resin, resistant against flying sparks
and radiant heat.

Clear opening: Length           m, Width            m

                         Pcs.


 It.   3:  Heatstop glazing

             for use in conjunction with the continuous rooflight
             comprising a highly reflecting surface providing an additional
             reduction of the heat transmittance.

                         Pcs.


 It.   4:  Full-perimeter crown (supported)

Steel sheet thickness acc. to static requirements, 450 mm height,
galvanized, arranged vertically, ready for assembly of a
80 mm thermal exterior insulation provided by customer, supported, including
the required diagonal ties and struts.

         Pcs.           each            running meter.


 It.   5:  Full-perimeter crown (unsupported)

Steel sheet thickness acc. to static requirements, 450 mm height,
galvanized, arranged vertically, ready for assembly of a
80 mm thermal exterior insulation provided by customer, unsupported for a
support-to-support distance up to 7.50 m, including the required
diagonal ties and struts.

         Pcs.           each            running meter.



 
20/32/05.05
TOPLINE – Skylight SystemTOPLINE
 

 It.   6:  Crown adapter profiles

Material thickness acc. to static requirements, blank ca. 250 mm,
galvanized, adapted to existing frame head for accommodation of the
Proline continuous rooflight.

         Pcs.           each            running meter.


 
 It.   7:  Crown coating

to be used in conjunction with the steel crown, installed by customer,
similar to RAL 9002, coil-coated.

         Pcs.           each            running meter.



It.  8: Crown insulation

to be used in conjunction with the steel crown, comprising an 80 mm thick mineral-fibre insulation – thermal conductivity group 040,
(for trapezoidal sheet or ISO roofs).

         Pcs.           each            running meter.



 It.   9:  Crown insulation – PU insulation

to be used in conjunction with the steel crown, comprising 80 mm thick      
PU rigid foam panels laminated on one side – thermal conductivity group 030,
(for foil or bitumen roofs).

         Pcs.           each            running meter.





20/33/05.05
TOPLINE – Skylight SystemTOPLINE
 

It.  10:  Crown film

Assembly of a roof foil strip provided by customer for installation
between the crown and the continuous rooflight.
This item includes the laying and workmanlike
welding of the corner section.
Complete sealing to the roof covering is conducted by customer.

         Pcs.           each            running meter.




 It.   11: Crown cover plate

to be used in conjunction with the steel crown, comprising an edged
1.0 mm thick aluminium plate, as-rolled finishing,
mounted as top flashing, ready for accommodation of the
existing roof connection plate.

         Pcs.           each            running meter.




 It. 12:  Crown connection plate

to be used in conjunction with the steel crown, two-piece plate,
comprising a sheet-aluminium top flashing,
as-rolled finishing, and a bottom sheet-steel flashing,
coated using a RAL colour at customer’s choice,     
ready for connection to an existing roof, including
profile filler.

         Pcs.           each            running meter.





20/34/05.05
TOPLINE – Skylight SystemTOPLINE
 

 It. 13:  Ventilation damper EL 1.10 m  x 1.98 m

for use in conjunction with the continuous rooflight incl. the electrical
ventilation system comprising an electric motor 230 V/50 Hz,
300 mm Hub, continuously variable, with automatic shut-off.
Wiring and cabling is performed by customer.

         Pcs.

It.  14: Ventilation damper PN 1.10 m x  1.98 m

for use in conjunction with the continuous rooflight incl. the
pneumatical  ventilation system comprising an pneumatical cylinder
300 mm Hub, operating pressure 5 – 8 bar, diameter 32 mm,
secured in both extreme positions.

         Pcs.



It.  15: SHE damper 1.10 m  x 1.98 m

for use in conjunction with the continuous rooflight as smoke and heat
exhausting (SHE) device according to DIN EN 12101-2, Aw = 1,634
m², incl. the automatic pneumatical natural smoke exhausting system
comprising a crossbeam, a pneumatic cylinder, a thermal trigger incl.
CO2 cartridge (opening at 68 °C).

         Pcs.


It.  16: SHE damper 2.30 m  x 1.98 m

for use in conjunction with the continuous rooflight as smoke and heat
exhausting (SHE) device according to DIN EN 12101-2, Aw = 3,188
m², incl. the automatic pneumatical natural smoke exhausting system
comprising a crossbeam, a pneumatic cylinder, a thermal trigger incl.
CO2 cartridge (opening at 68 °C).

         Pcs.



20/35/05.05
TOPLINE – Skylight SystemTOPLINE
 

 lt. 17:  Single-casement domelight SHE – double wing

Nominal dimension:                     m / crown:              cm

for use in conjunction with the continuous rooflight as smoke and heat
exhausting (SHE) device according to DIN EN 12101-2 incl. the
natural smoke exhausting system. Automatic opening at 68 °C or
manually triggering with an alarm unit connected by pipes.
The mounting is possible at the crown or the mounting bars.


         Pcs.


         mounting between head ends

         mounting at the mounting bars

         mounting at the start or the end of the roof light


 lt. 18:  emergency finned ventilator

Nominal dimension:                     m / crown:              cm

for use in conjunction with the continuous rooflight as smoke and heat
exhausting (SHE) device according to DIN EN 12101-2 incl. the
natural smoke exhausting system. Automatic opening at 68 °C or
manually triggering with an alarm unit connected by pipes.
The mounting is possible at the crown or the mounting bars.



         Pcs.


         mounting between head ends

         mounting at the mounting bars

         mounting at the start or the end of the roof light

 



20/36/05.05
TOPLINE – Skylight SystemTOPLINE
 
  

 It. 19:  Ventilation system EL 300 mm Hub

for use in conjunction with the damper of the natural smoke exhaust system, comprising an electric motor
230 V/50 Hz, 300 mm Hub, continuously variable, with automatic
shut-off.
Wiring and cabling is performed by customer.

      
         Pcs.

It.  20: Ventilation system PN 300 mm Hub

for use in conjunction with the damper of the natural smoke exhaust system, comprising a pneumatic cylinder,
300 mm Hub, operating pressure 5 – 8 bar, diameter 32 mm,
secured in both extreme positions.

      
         Pcs.



 It. 21:  Surface type push button

for operating the electrical ventilation system (“OPEN” - “SHUT”).
Wiring and cabling is performed by customer.

         Pcs.


 It. 22:  Automatic wind and rain shutter

 for safely closing the ventilation damper in case of precipitations,
snowfall, heavy fog or high wind speed, comprising
a surface-mount switch and control box and a
heated rain sensor plate and an electronic anemometer.
The dampers can be opened manually after the rain sensor plates
are dry again.
Wiring and cabling is performed by customer.


         Pcs.

20/37/05.05
TOPLINE – Skylight SystemTOPLINE
 

 It. 23:  Alarm box (“OPEN”)

surface type, for manual activation of the natural smoke
exhaust system, red painting, including one CO2 cartridge,
lock, break glass and a striker valve.

         Pcs.



It.  24: Alarm box (“OPEN” with electric supply)

surface type, red painting, including one CO2 cartridge,
lock, break glass and a striker valve,
plus electromagnet (12V, 24V or 230V) for
tripping of the natural smoke exhaust system through
the control unit of the fire-alarm or natural smoke exhaust system provided by customer.

         Pcs.


 It. 25:  Alarm box (“OPEN” / “SHUT”)

surface type, for manual activation of the natural smoke and heat
exhaust system. Comprising a lockable steel sheet enclosure,
red painting, including two CO2 cartridges,
reverse valve, lock, break glass and a striker valve.

         Pcs.

 




20/38/05.05
TOPLINE – Skylight SystemTOPLINE
 

It.  26:  Single-line compressed-air pipe

Cu pipe, 6mm * 1mm, c / w threaded assembly
and fixing work. Charges will be based on installed dimensions.
Installation visible “Surface-Mount”.

         Pcs.           each            running meter.




It.  27:  Twin-line compressed-air pipe

Cu pipe, 6mm * 1mm, c / w threaded assembly
and fixing work. Charges will be based on installed dimensions.
Installation visible “Surface-Mount”.

         Pcs.           each            running meter.




 
 It.   28: Pneumatic valve compatible

(“OPEN-SHUT”“), for controlling the pneumatic ventilation facility,
comprising an air control block including threaded assembly,
steel sheet enclosure, surface type, light blue painting,
compatible with CO2 alarm box as priority control.

         Pcs.


20/39/05.05
TOPLINE – Skylight SystemTOPLINE
 

 It.   29: Maintenance unit

comprising a moisture separator with manometer and
pressure reducer (compressed-air supply is provided by
customer).

                         Pcs.



It.  30:  VdS acceptance

Charges for an individual acceptance of the natural smoke exhaust system
acc. to DIN EN 12101 or VdS 2159 to be conducted by the Verband
der Schadensversicherer e.V. Köln as requested by the builder-owner.

         Pcs.




It.  31:  Expert acceptance

Acceptance of the natural smoke exhaust system
acc. to DIN 18232 conducted by smoke and heat exhaust experts.

         Pcs.

 
20/40/05.05
TOPLINE – Skylight SystemTOPLINE
 

It.  32:  Random method

Charges for participation in the random testing of the
natural smoke exhaust system conducted by VdS,
issue of a certificate on the compliance of the natural smoke exhaust system
acc. to DIN EN 12101 and / or VdS 2098/ 2159.

         Pcs.



It.  33:  Assembly flatrate

for carriage, travel to the site, construction site equipment, offloading and transportation
onto the roof.

         Pcs.


It.  34:  Flat-rate freight charge

for delivery free on site, w/o offloading, w/o assembly

         Pcs.








 

 

(c) copyright by INDU-LIGHT all rights reserved, for any questions regarding this site please contact webmaster@indu-light.de (20061027)